Auction report
2016 Caterpillar 272D2
Auction closed
- Auction house
- Smith & Broughton
- Location
- Midland WA
- Lot
- 242003-1
- Auction date
- 13 Aug 2026
- Hours
- 2,972 hrs
- Serial
- MD200379
227+ photos in the full report, tagged to their system
24 July 2026
Inspected
227+
Photos taken
9
Systems covered
5
Tests run
Systems walked: 100 General Walkaround - 120 Cab & Controls - 130 Electrical - 200 Engine - 600 Frame & Chassis - 700 Hydraulics - 850 Wheels & Tyres - 900 Attachments - 960 Access Systems | Tests: E-stop function - Reverse alarm - camera and horn - Lighting under auxiliary power - Cat ET PSR download
The full report
Price on request
The complete Asset Condition Report on this machine: every system rated, the full severity-ranked defect register and the photo appendix, plus every inspection photo at full resolution. The auction has closed; the report remains available, including to the winning bidder.
Request the reportNon-exclusive: any bidder can buy the same report.
RedSpec does not sell machines, does not do the repair work, takes no commissions and has no dealer or vendor ties. The report answers to the bidder who buys it.
See a real report first
Open PDF
A complete RedSpec report on a different machine, start to finish. Same format, same taxonomy and same photo appendix as the one on this Caterpillar. Read it before you decide.
What's in the full report
- Photos tagged to their system227+
- Condition rating per systemGood Fair Poor
- Category every defect taggedSafety Compliance Productivity Cosmetic
- Leak class where it appliesClass 1 Class 2 Class 3
- Reference on every findingSMCS FIG.
Representative finding
Lift chart and safety decals degraded
The 5,300 kg rated-load lift chart decal was largely destroyed and illegible. Safety decals across the machine were sun-faded.
1 of 26 classified findings in the full register
Lot notes
Inspected at the Smith & Broughton Midland yard on a public inspection day. The machine was started on auxiliary battery power and run in short periods; function testing was limited by the machine state on the day. The full report records what was and was not assessable, with 227 photographs and the ECM history from the machine (Cat ET PSR download, XML) included.
Scope and limits
- Condition as observed on the inspection date, at a public inspection day, with the access allowed on the day.
- Anything not accessible on the day is recorded as not assessed, not guessed at.
- Auction inspection scope: what a stationary machine can show, documented per the RedSpec ACR method. Function and operational testing sit outside auction-day access; commission an inspection for the complete ACR.
- No fitness-for-service sign-off and no purchase recommendation. RedSpec finds, flags, presents; the bid is yours.
Auction alerts
One email when new lots are inspected and reports go live. No newsletter, no filler.
Signed up. You'll get an email when the next reports go live.
That didn't send. Email us at [email protected] and we'll add you.
Get eyes on the machine.
Tell us the machine, where it is and the decision the report has to support. Quote usually within one business day.